BRAND | Integra Metering AG (formerly Aquametro) |
Product | 94588 |
Internal code | IMP3308502 |
Weight | 14.2 |
Technical specification | KMS 100 MID Q160 BL360 PN16 Bulk meter cold water RUBIN KMS Measuring prinzipleWoltman-Turbine MID appendix MI001 directives 2004/22/EG Nominal diameter: DN 100 Nominal pressure: PN 16 Protection class: IP 68 Process connection: Flange EN 1092-1 Installation length: 360 mm Installation position: horizontal and vertical Inlet and outlet run: U0 D0 Temperature range medium: 0.1 - 50 °C Permanent flowrate Q3: 160 m3/h Measuring range: v R160 / h R315 Accuracy class: 2 Pressure loss at Q3: 0.34 bar Approvals: SVGW drinking wate |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Integra Metering AG (formerly Aquametro) - 94588 number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Ukraine Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
MeiStream RUBIN cold water meters Nominal size: DN 50 Flange connection: EN 1092-1 Nominal pressure: PN 16 bar Overall length: 200 mm Mounting position: horizontal / vertical Protection: IP 68 Temperature max .: 50 ° C Overload flow Q4: 90 m3 / h Permanent flow rate Q3: 50 m3 / h Transition flow rate Q2: 0.4 m3 / h Minimum flow rate Q1: 0.15 m3 / h Smallest readable amount: 0.5 l Registration capacity: 1 million m3 Measuring principle: Woltman turbine Measuring range delivery designation: R 100
PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
CE test water meter R49 DN15-32
CE test water meter R49 DN40-50
System module aquapuls® For retrofitting aquabasic® cold water meters. Pulse value 1 l / pulse with return compensation. Switching capacity 220 mA / 48 VDC. Degree of protection IP 68 with 1.5 m cable, fixed. With battery power
DOMINO ® ARD structure group - Reguliergetriebe - Roller 6 digits, with RV Reed pulser, 48 VAC / DC, 50 mA, 2 W Specifications: Recording capacity Roller: 107 l Smallest readable Quantity: 0.1 l Pulse Value: 1 l
Fuel Oil Meter
CONTOIL® oil meter VZO 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter
P/N 92280 Aquametro Oil Meter
VZO 25 FL 180 / EXP 10-20K
[CONTOIL ® fuel oil meters Reed pulser Pulse value 1.25 ml Nominal width: 4 mm With internal thread copper pipe: 1/8 " Nominal pressure: PN 25 Maximum permissible temperature: 50 ° C Mounting position: horizontal / vertical Largest flow Qmax. 80 l / h In continuous operation: 50 l / h Error of measurement: 1-80 l / h + / - 1% of the measurement error Recording capacity Roller 100 000 liters With built-on Reed pulser RE max:. 48V AC / DC, max. 50 mA, max. 3 VA Pulse value: 0.00125 l]
vzo-4 fuel counter
MOTOR AC230V 50/60HZ DN25 WITH CAPACITOR AND GEAR FOR ACTUATOR TYPE: 2KN:
fuel counter gear
fuel counter gear
(92042, CONTOIL® oil meter Reed pulser Pulse value 0.1 l, nominal width: 15 mm DN With 3/4 "thread for fittings: 1/2" Overall length: 165 mm Nominal pressure: PN 16 bar Max. Permissible temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax .: 600 l / h In continuous operation Qn .: 400 l / h Minimum flow rate Qmin .: 10 l / h Bias: 10-600 l / h ± 1% of reading Repeatability equal / better than 0.2% Total amount on roller 1 000 000 l Smallest readable Quantity: 0.01 l Pulser Reed, max.48 V AC / DC, 50 mA, 2 W Pulse value: 0.1 l Measuring principle: piston ring)
Oil meter with roller Measuring accuracy ± 1% Medium temperature to 130 ° C Roller counter with pulse generator, optionally Reed (RV) or Namur (IN) VZO 15 ... 50 with Flange EN 1092-1, PN 25
fuel meter
TOPAS hot water meter, Nominal Size: DN 32,With thread 1 1/2 "(for screw 1 1/4"),Nominal pressure: PN 16 bar,Overall length: 150 mm,Mounting position: vertical falling,Temperature max .: 90 ° C,Overload flow Q4: 12.5 m3 / h,Permanent flow rate Q3: 10 m3 / h,Transition flow Q2: 12:16 m3 / h,Minimum flow rate Q1: 0.1 m3 / h,Measuring range: R 100,Smallest readable amount: 0.1 l,Registrable: 100000 m3,Measuring principle: multi-jet turbine, dry running
pair fittings
CE test hydr. Encoder EN1434 DN15-32
level indicator
aquabasic® Kaltwasserzähler
96166 CE-Prüfung Wasserzähler R49 DN15-32